<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-17 05-01-40
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 58 dBuV YLEX
Pilot RDS Phase Difference
7.5 kHz 2.3 kHz 55 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 64 kHz 18977 1,2805
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,7 dBr 4,42 dBr 5,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 5:01, 17.07.2025
RT
-
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6205, 6201, 6203, 6207
FM Scope Max at: 64 kHz MIN: 10 kHz % above 76 kHz: 1,2805 Acquired: 2025/07/17 5.00.37 Total samples: 18977 Equivalent time: 0:15:48 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 5,3 dBr MIN: 2,7 dBr AVE: 4,42 dBr % above 12,2 dBr: 0,0 Last value: 2,7 dBr (2025/07/17 5.00.36) 04.46 04.48 04.50 04.52 04.54 04.56 04.58 05.00 0 2 4 6 Pm [dBr]